Laverock Hall Bridge

Laverock Hall Overbridge was suffering typical corrosion problems associated with leaking bridge deck joints, exhibiting significant concrete spalling as a result of chloride induced steel reinforcement corrosion. Northumberland County Council have an obligation to maintain a number of structures distributed over a wide geographical area.

Location

Cramlington, UK

Client

Northumberland City Council

Completed

July 2006

Structure

Bridges

Laverock Hall Bridge - icon problem

The Problem Identified

Deterioration of the beams was visible due to the corrosion activity and technical analysis showed chloride levels in the concrete were likely to lead to further corrosion problems.

Laverock Hall Bridge - icon solution

The Solution Developed

Northumberland County Council were keen to have a low maintenance, long term solution to the reinforcement corrosion problems at Laverock Hall Bridge. A DuoGuard™ hybrid anode system was designed to halt ongoing corrosion and prevent further damage. Using an external power source, an impressed current was applied to stop active corrosion and render the steel passive. The DuoGuard 500 anodes were then disconnected from the power source to self-generate a galvanic current, sufficient to maintain steel passivity and control corrosion.

Monitoring equipment and measurement probes were installed in the treated zones to allow remote monitoring of system performance. Results obtained from the monitoring system have indicated a potential anode lifetime of 50+ years.

Laverock Hall Bridge - icon benefits

The Benefits Provided

Corrosion related deterioration of Laverock Hall Bridge has been halted. After the initial power period using an external power source, the DuoGuard system is self powered thus minimising future maintenance requirements and associated life costs.

Temporary impressed current phase
Temporary impressed current phase

Learn more about DUOGUARD™ & MN15 REFERENCE ELECTRODE

DUOGUARD™ - duoguard v2

DUOGUARD™

DuoGuard™ Hybrid Anode halts reinforced concrete corrosion for targeted protection.

Find out more
MN15 REFERENCE ELECTRODE - mn15 v2

MN15 REFERENCE ELECTRODE

MN15 Reference Electrode, Manganese Oxide electrode for monitoring structures.

Find out more

Can we help?

For assistance and guidance from the industry experts please leave your details below and we’ll be in touch.








    More Bridges