The DuoGuard™ Hybrid Anode

stops corrosion and extends structural life

  • 2nd generation targeted protection
  • 20 – 50 years protection
  • Benefit of both impressed current and galvanic cathodic protection, no permananet power source required
  • Manufactured in the UK to ISO9001

Our unique DuoGuard range of discrete anodes features innovative dual technology to arrest steel reinforcement corrosion within 7 days. DuoGuard™ is installed into concrete structures to stop reinforcing steel corrosion caused by chloride salts and carbonation. It can be used to protect contaminated but unspalled concrete saving the time and cost of replacing the concrete material. With a long system lifetime the DuoGuard™ anode provides a cost effective, maintenance free method of corrosion protection.

Corrosion

Problem

DuoGuard™ combats the two main types of corrosion found in reinforced concrete structures.

- Carbonation induced – exposure to atmospheric carbon dioxide combined with prolonged contact to sufficient moisture and oxygen can leave steel vulnerable to corrosion.

Keep Reading

- Chloride induced – if chloride in the form of inherently mixed set accelerators or external aggressive salts permeates reinforced concrete in sufficient quantities, an aggressive form of corrosion can be initiated.

When either or both of these take hold in a structure, this can lead to the concrete cracking and being displaced as the steel reinforcement expands and pushes out. The corrosion and its effects often propagate very quickly – so it is crucial to be proactive in assessing and fixing the issue.

duoguard anodes

DuoGuard™ Anodes

CPT DuoGuard™ anodes feature new generation electro-chemical technology to stop reinforcing steel corrosion caused by chloride salts and carbonation for up to 50 years.

Keep Reading

The full package: CPT also includes in the anode price all the ancillary materials needed for DuoGuard™ installation, including wires, connectors and embedding mortar.

Anodes are available in 5 sizes to suit any structure:

DuoGuard™ 175: 42 mm long x 18 mm diameter
DuoGuard™ 350: 77 mm long x 18 mm diameter
DuoGuard™ 500: 110 mm long x 18 mm diameter
DuoGuard™ 750: 165 mm long x 18 mm diameter
DuoGuard™ 1000: 220 mm long x 18 mm diameter

duoguard installation

Installation

DuoGuard™ anodes are installed into contaminated areas of reinforced concrete, identified as being at risk of corrosion, by simply drilling 30mm diameter holes and embedding the anodes in DuoCrete SD mortar. These are then temporarily connected in groups to a power supply using titanium wire – just a couple of connections are required for a circuit of up to 200 anodes. The system is discrete with no surface wiring or permanent control systems – totally vandal proof.

duoguard how it works

How it works

DuoGuard™ is a hybrid treatment. During treatment a sacrificial anode is used as both an impressed current and galvanic anode. Initially, a constant voltage power supply is used to drive a high current from the installed anode to re-passivate the corroding steel, typically for one week. The same anode is then connected directly to the steel to provide maintenance free cathodic protection by means of a galvanic current. The hybrid system means that the requirement for a permanent power supply is eliminated and DuoGuard offers the advantages of a galvanic anode system, requiring little to no maintenance. The system can be designed to meet BS EN ISO 12696:2012 the international standard for cathodic protection.

DuoGuard™ - Long Term Performance Data

The graph below shows the protective current produced by a zone of eight anodes over a 9.5 year period at Whiteadder Bridge in Northumberland. This bridge spans a flood plain and DuoGuard™ hybrid anodes were installed into the bridge piers to control corrosion back in April 2007. The anodes can be seen to be extremely reactive to local conditions with peaks in current output coinciding with river floods and soaking of the bridge piers. During drier times the current is reduced and anode life is preserved. Corrosion rate measurements have been independently taken by Aecom and these are shown along the horizontal axis. In accordance with BS EN ISO 12696:2012, the international standard for cathodic protection of steel in concrete, the steel has remained passive throughout the monitored period with all corrosion rates measured at less than 2mA/m2 steel. Whiteadder Bridge is one of many sites where long term performance has been monitored, providing reassurance that the DuoGuard™ system will provide reliable, self-regulating, maintenance free protection.

Whiteadder Bridge

concrete protection monitoring